Additional Configuration Options
Additional configuration options have been added to the MOS Gateway configuration file. These
options will allow MOS Gateway to communicate more efficiently with MOS devices that
support these additional commands.
handlesRoStoryMoveMultiple – Setting this option to YES will require less
communication between the MOS Gateway and the MOS device to move a block of
stories in the rundown. With this option set to NO, the stories will be deleted and
reinserted into the rundown on the MOS device one at a time. Check with your MOS
device vendor to determine if they support this command.
handlesRoItemLevelCommands – Setting this option to YES will require less
communication between the MOS Gateway and the MOS device when changing,
inserting, or deleting a MOS item in a story. The YES setting allows the MOS Gateway
to manipulate items in a story without requiring the entire story to be deleted and
reinserted in the rundown at the MOS device. Setting this to NO will prevent MOS
Gateway from using the item level commands. Check with your MOS device vendor to
determine if they support the roItemInsert, roItemDelete and roItemReplace commands.
sendRoCreateOnStartLoad – Setting this option to YES will send a blank roCreate to the
MOS device then add each story separately. Using this will cause the rundown to take
an overall longer time to load the entire show, but will permit the stories at the beginning
of the rundown to be loaded quicker than if set to NO. Setting this to NO will cause the
show to be loaded in one large roCreate message. This will take an overall shorter time
to load the entire show, but no stories will display on the MOS device until the entire
show is loaded. If no entry is made for this option it will default to NO.
Fixed Problems
MOS Gateway does not accept fractional timebase
MOS Gateway 1.0 did not accept fractional timebase. This problem has been corrected in
MOS Gateway 2.0.
MOS Gateway stops responding if a MOS Device is shutdown while a show is loaded
In previous versions of MOS Gateway, shutting down a MOS Device while a show is
loaded, then trying to unload the show from iNEWS would cause the MOS Gateway to
wait indefinitely for a response from the MOS Device. This problem has been fixed in the
latest build of MOS Gateway. The MOS Gateway will no longer wait for a response from
a MOS Device if that MOS Device is not available on the network.
MOS Gateway Logger cannot log some extended characters
In previous versions of MOS Gateway, the MOS Gateway Logger could not log some
extended characters in the log file. This problem has been fixed in the latest build of
MOS Gateway.