Installing the Failover Hardware Components
20
Installing the Failover Hardware Components
A failover cluster system includes the following components:
• Two Interplay Engine nodes or two Interplay Archive nodes (two AS3000 servers)
• One of the following shared-storage RAID arrays:
- Infortrend S12F-R1440
- HP MSA 2040
The following topics provide information about installing the failover hardware components for
the supported configurations:
•
“AS3000 Slot Locations” on page 20
• “Failover Cluster Connections: Avid ISIS, Redundant-Switch Configuration” on page 21
• “Failover Cluster Connections, Dual-Connected Configuration” on page 24
AS3000 Slot Locations
Each AS3000 server requires a ATTO Celerity FC-81EN Fibre Channel host adapter to connect
to the shared-storage RAID array. The card should be installed in the top expansion slot, as
shown in the following illustration.
Avid AS3000 (Rear View)
Adapter card
in top PCIe slot