<network>ncs_gateway_host_name</network>
</names>
Here the ncs_gateway_host_name should be replaced by the actual host name of the computer
that runs the NCS Gateway. This value should also remain the same among all the region
<mosDevice> groups, since a single NCS Gateway controls all the regions on a MAV Server.
Known Problems & Limitations
iNEWS Workstation
SONY: Max of 10 ActiveX connections to NewsBase if Sony's Database is on NT
Workstation (AR 10217)
NT Workstation 4.0 allows only 10 concurrent connections. The Sony Filing Control and
Material List Control each require a connection to the Sony database, limiting the number of
users.
"Import from plugin" option in popup menu not working (AR 10165)
The "Import from Plugin" option in the popup menu in the story body is not displaying the
Active X control that is currently open on screen. Instead, it says "not available". The "Import
from Plugin" option in the Story drop menu does, however, display the open ActiveX control,
so it appears that the problem is specific only to the popup menu. The "Replace from Plugin"
popup menu option does display properly if you right click on an existing MOS item in the
story body.
Also, the “Import from Plugin” and “Replace from Plugin” options do not work (in any of
the menus) when using the Sony Filing Control or the OmniBus Desktop Controls. This is a
limitation of these particular controls, not a limitation of the iNEWS Workstation.
MOS Gateway
Gateway aborts if download attempted when Sony NCS Gateway only made metadata
connection (AR 9740)
Normally, two connections are made between the iNEWS and Sony gateways, as shown in
the Sony gateway log. Under certain conditions that we have not yet learned to consistently
reproduce, only the metadata connection was being made. The Monitor Load command
would then cause the iNEWS MOS Gateway to abort.
Sometimes can't stop router service (AR 9927)
Under certain conditions that we have not yet learned to consistently reproduce, the MOS
Gateway Router service cannot be stopped by the Services control panel.
MOS Gateway aborts if Attachments not found in story (AR 9737)
The iNEWS Workstation can apparently corrupt a story with MOS items to the point where
there are grommets indicating MOS production cues but no actual MOS items attached to
those production cues. MOS Gateway would abort upon receiving the story. This seems to
happen infrequently; the steps to reproduce it are not known.