Errors
107
Action: Open the MOS Gateway configuration file. Edit the
<in_lower> value in the <tcpPorts> group to insert a port number.
Stop and restart the Router.
Error: Bad In MOS Upper port value.
Location: Event Log Source: MOS Gateway Router
Category: Startup
Action: Open the MOS Gateway configuration file. Edit the
<in_upper> value in the <tcpPorts> group to insert a port number.
Stop and restart the Router.
Error: Bad Out MOS Lower port value.
Location: Event Log Source: MOS Gateway Router
Category: Startup
Action: Open the MOS Gateway configuration file. Edit the
<out_lower> value in the <tcpPorts> group to insert a port number.
Stop and restart the Router.
Error: Bad Out MOS Upper port value.
Location: Event Log Source: MOS Gateway Router
Category: Startup
Action: Open the MOS Gateway configuration file. Edit the
<out_upper> value in the <tcpPorts> group to insert a port number.
Stop and restart the Router.